Hot tub heating guide

What Does It Really Cost To Heat A Hot Tub?

Almost all the electricity a hot tub uses goes on one job: putting back heat that escapes. Here's where that heat goes, how insulation and the weather change it, and how a heat pump makes the same heat for a fraction of the electricity. Then work out the figures for your own tub.

Skip to the calculator ↓
£838a year to heat a typical tub with its built-in heater
85%of that is heat escaping with the cover on
65–73%less with a heat pump doing the same job

Our example throughout: a 1,400 litre tub (6–7 seats) at 38°C with air-pocket insulation and a 3 kW heater, used three times a week for 30 minutes, refilled four times a year, in the Midlands, at 26.1p per kWh.

01

Where the heat goes

A hot tub is a large tank of water kept far warmer than the air around it, and heat always flows from warm to cold. Your heater's job is to replace it. In our example the yearly bill of £838 splits three ways:

Cover on£70985%Through the cabinet and cover, all day
Sessions£799%From the open water while you're in it
Refills£516%Heating fresh water after each refill

The cover-on loss is the big one, because it never stops. Even with the lid shut, warmth leaks through the cabinet walls, the floor and the cover, 24 hours a day.

Taking the lid off is costly while it lasts. Open water loses heat quickly, and about 76% of it goes as evaporation: the steam you see on a cold evening is heat leaving the tub. A 30-minute soak on a January evening loses about 2.1 kWh, enough to drop the water about 1.3°C.

Refills cost about £13 each with the heater: 1,400 litres of mains water have to be warmed by more than 20°C in summer and over 30°C in winter.

In short

Most of the bill is heat seeping out with the cover on, all day, every day. That's where better insulation and a more efficient heater pay off.

02

Insulation makes the biggest difference

How fast a tub loses heat with the cover on comes down to its insulation. We describe it as a heat-loss rate: how many watts escape for every degree the water is warmer than the air. A well-insulated tub loses about 43% less than a basic one:

InsulationA January dayHeater, per year
BasicCheaper tubs with thin panels or bare cabinets.11.4 kWh£1,032
Air-pocketA thermal wrap with an air gap between shell and cabinet.8.9 kWh£838
Full foamCabinet filled with open-cell foam around the shell.6.5 kWh£644

The cover is part of the insulation too. A heavy, well-fitting cover with its seals intact keeps in far more heat than one that has soaked up water or no longer sits flat. Checking it costs nothing.

You can't see inside the cabinet, and makers rarely publish a figure. That's why the calculator lets you enter your actual usage instead: it then works out the heat-loss rate that matches your tub.

In short

A fully foamed cabinet and a good cover can take hundreds of pounds a year off the bill before you change anything else.

03

Winter costs more, and so does the north

Heat loss depends on the gap between the water and the air. In the Midlands, the average January day is 4.2°C and the average July day 16.5°C, so holding 38°C water loses about 57% more heat in January than in July.

Where you live matters too. January averages 4.9°C in the south east of England and 2.9°C in the north of Scotland (Met Office averages for 1991–2020). The calculator uses the monthly averages for your region.

In short

In the Midlands, holding temperature costs about 57% more in January than in July.

04

Every degree counts

Keeping the water at 36°C instead of 38°C cuts the heating bill by about 7%, roughly £63 a year in our example, because the gap to the outside air is smaller all year round.

If you're away for a few days, turning the temperature down saves more than it costs to heat back up.

In short

Lower the temperature when you can, especially when you're away.

05

How a heat pump does the same job for less

A built-in heater turns electricity straight into heat: 1 kWh in, 1 kWh of heat out. A heat pump works like a fridge in reverse. It uses electricity to move heat that's already in the outdoor air into your water. That's why it can deliver several kWh of heat for each kWh it uses.

That ratio is called the COP (coefficient of performance). It depends on the weather: there's less heat to collect from cold air. Poolex rates the O'Spa 7kW at a COP of 3.6 at 15°C, 3.0 at 5°C and 2.65 at 0°C. Even on a freezing day it makes more than two and a half times the heat of a heater for the same electricity.

Two more things help. Cooler water is easier to heat, so warming a fresh refill is more efficient than holding the last few degrees. And an inverter heat pump such as the Ice Spa can slow down to match what the tub needs. When it's only holding temperature it runs gently, where it's most efficient: a COP of 4.2 at 15°C, against 3.7 flat out.

Our example tub, heated byPer yearSaving
3 kW built-in heater£838—
O'Spa 5kW heat pump£294£544 · 65%
O'Spa 7kW heat pump£258£580 · 69%
Ice Spa 7kW heat pump£230£608 · 73%
In short

A heat pump cuts the cost of every kWh of heat, and insulation cuts how many you need. They work best together.

06

Getting a reliable estimate for your tub

The most accurate starting point is what your tub uses now. If it's on a smart plug, or your energy supplier's app shows a clear daily jump, note the figure and which month it's from. A January figure and a July figure from the same tub are very different, and the calculator matches yours to that month's weather.

A smart plug also measures the circulation pump, so take off about 1 kWh a day for that. No figure? Choose the insulation that best matches your tub, and adjust the sessions, temperature and tariff to suit how you use it.

In short

A winter figure from a smart plug gives the most reliable result. Try it below.

Calculator

Work It Out For Your Tub

Tell us about your tub, how you use it and your electricity tariff. We work out the heating cost month by month for your region, with your built-in heater and with each of our heat pumps.

Your tub

Size
litresPick the nearest size, or type the litres from your tub's manual.
Built-in heater

Heat loss

Cabinet insulation
A thermal wrap with an air gap between shell and cabinet.

How you use it

Your electricity

Unit ratep per kWh

Where you live

Your estimate

Heater now£838a year
With heat pump£258O'Spa 7kW
You save£580a year · 69%
Pays back in2 years, 10 months£1,657 installed

In Jan, each 30-minute session with the lid off loses about 2.1 kWh (the water drops about 1.3°C). The O'Spa 7kW wins that back in 38 min.

Compare heat pumps

Installation
Heat pumpInstalledPer yearSavingPaybackHeat-up
£1,446£294£544 · 65%2 years, 8 months25 h
£1,657£258£580 · 69%2 years, 10 months16 h
£2,110£230£608 · 73%3 years, 6 months14 h

Recommended: the lowest total cost over 10 years (price, installation and electricity) among the pumps that can heat your tub from cold within 48 hours in Jan. Your built-in heater takes 20 h.

Month by month

Built-in heaterO'Spa 7kW
£0£50£100JanFebMarAprMayJunJulAugSepOctNovDec
Show as a table
MonthOutdoorHeaterHeat pump
Jan4.2°C£85 · 324 kWh£28 · 109 kWh
Feb4.5°C£77 · 295 kWh£26 · 98 kWh
Mar6.3°C£80 · 305 kWh£26 · 98 kWh
Apr8.6°C£72 · 275 kWh£22 · 85 kWh
May11.5°C£67 · 257 kWh£20 · 75 kWh
Jun14.4°C£58 · 223 kWh£16 · 62 kWh
Jul16.5°C£55 · 211 kWh£15 · 58 kWh
Aug16.2°C£56 · 213 kWh£15 · 59 kWh
Sep13.8°C£60 · 229 kWh£17 · 64 kWh
Oct10.4°C£70 · 267 kWh£21 · 80 kWh
Nov6.9°C£76 · 290 kWh£24 · 92 kWh
Dec4.5°C£84 · 321 kWh£28 · 107 kWh

Over 10 years

Built-in heaterO'Spa 7kW, installed
£0£5,000£10,000NowYr 1Yr 2Yr 3Yr 4Yr 5Yr 6Yr 7Yr 8Yr 9Yr 10

The dot marks where the heat pump has paid for itself.

Want a fixed price for your tub?

Book a free home survey. We'll bring these figures with us, check your tub and give you one fixed price.

Book a survey with these figures
How we work it out

Weather. Average outdoor temperature for each month in your region, 1991–2020, from the Met Office (HadUK-Grid regional series).

Heat lost with the cover on. The insulation options are heat-loss rates for a 1,400 litre tub (14, 11 and 8 W per °C), scaled to your tub's size. If you enter your usage instead, we find the heat-loss rate that matches it.

Heat lost with the lid off. Evaporation from the open water uses the ASHRAE swimming-pool equation, plus convection to the air, assuming 80% humidity and a light 1 m/s breeze. A 1,400 litre tub has about 3.2 m² of open water. Jets and air blowers increase the loss.

Heat pump efficiency. COP and heat output come from the Poolex manuals at 38°C water and different air temperatures (O'Spa 54 and 74, Ice Spa 70). We interpolate between the rated points and don't go above the 15°C ratings. Cooler water heats more efficiently, so heat-ups from cold use the higher 26°C-water ratings. The Ice Spa is an inverter: holding temperature uses its lowest-output rating, while heat-ups, recovery after a session and off-peak heating use its full-output rating.

Refills. Each refill starts at mains temperature (the month's outdoor average, at least 4°C) and is heated to your set temperature at full output, counting cabinet losses on the way.

Not included. The circulation pump's own electricity (the same with or without a heat pump), standing charges and future price changes. Prices are our current fixed installed prices.

Sources: Met Office HadUK-Grid regional mean air temperature series, monthly means averaged over 1991-2020 (www.metoffice.gov.uk/pub/data/weather/uk/climate/datasets/Tmean/date/<region>.txt, downloaded 2026-10-01). Poolex manuals: O'Spa 34/54/74 (technical characteristics, EN p.50) and Ice Spa 70 (202605 manual, EN p.56). Points are at 38°C water. copLow is the inverter's rating at its lowest output, copFull at full output (the same for fixed-speed pumps). water26Ratio is COP with 26°C water divided by COP with 38°C water, both at 15°C air.